104 Acme Packet 6100 Hardware Installation and Maintenance Guide
Fan speed
En
vironmental sensor
Po
wer supply
Voltage
Phy
sical interface cards
Each alarm is assigned a severity level, depending on the details of the fault.
Table 6 - 8. Descriptions of Alarm Severity Levels
Alarm Severity Description
Minor Functionality is impaired to a small degree (e.g., a single fan has failed)
Major Pending failures or unexpected events are imminent (e.g., an LOS)
Critical Catastrophic condition has occurred (e.g., the system is overheating)
Hardware and
Environmental
Alarms
This section provides details about hardware and environmental alarms.
Hardware
Te
mperature Alarm
The following table lists the hardware temperature alarm.
Table 6 - 9. Hardware Temperature Alarm Information
Alarm Name
Alarm
ID
Alarm Severity Causes Example Log Message
Graphic Display Window
Mes
sage
TEMPERATURE
HI
GH
65538 CRITICAL: >105°C
MINOR:
>95°C
Fans are obstructed
or
stopped. The room
is abnormally hot.
Temperature: XX.XXC
(where XX.XX is the
t
emperature in
degrees)
Temperature X C (where X
is
the temperature in
degrees)
If this alarm occurs, the Acme Packet 6100 turns the fan
speed up to the fastest possible speed.
MAJOR: >100°C